Fire Resistance Class: Determines the duration of fire resistance which is determined as a result of fire resistance tests specified in the European Standards under appropriate heating and pressure conditions of a building.
The objective of the Fire Code is to provide organization, training and supervision by taking pre and post fire measures and by making it possible to put out any type of fire that might outbreak during creating, building, operating and using processes in all kinds of constructions, buildings and facilities used by public and private institutions & organizations and real persons.
Fire resistand and smoke-proof wooden doors are doors that isolate a room/living space from the room the fire may outbreak, and ensure the safety and security of the people in the building for a certain period of time. In accordance with the fire code; we offer fire door solutions for hospitals, dormitories, schools, shaft doors, high-rise building entrances, fire halls, etc. Acccording to the regulations the smoke and fire resistance rates can change from 30 minutes to 120 minutes. 30 Minutes, 60 Minutes or 90 Minutes fire resistance options are available depending upon the situation, and place the door is used. Human safety & security comes before everything. Fire resistant doors are instrumental in keeping the fire under control, and have an important place in minimizing possible damages and casualties.
Fire doors keep the fire at a certain area, preventing it from spreading to another section of the building, and decrease the risk factor for the residents in the building by bringing the fire under control and slowing down the spreading speed of the fire. Fire doors require expertise from the very beginning of the production to the final touches in the installation process. Each and every stage of the production and installation has to be well in hands of experts.
All of our fire doors are subjected to fire resistance tests at internationally accredited testing laboratories, and certified with EI30-EI60-EI90 Fire Resistance Certification Documents. Following all these processes, serial production process can be commenced. As Indoor Life, if we have produced a model specific for your project, than we start the whole process from the beginning and get a whole new certificate for your specific model.
Fire doors, are the most important factors in buildings which blocks the fire and the smoke from spreading into other areas of the building, as well as helping people to evacuate the building safely and quickly. Depending on the functionality of the buildings, the characteristics of the fire doors are legally determined.
According to Article 50 of the Regulation on Fire Protection of Buildings, doors manufactured in accordance with TS-EN 1634: 2014 standards are generally required to be applied in HOSPITAL, SCHOOL, DORM and HOTEL projects.